Other

Effect of Oral Vitamin D3 on Dental Caries: An In-Vivo and In-Vitro Study.

Aim

Vitamin D3 plays an important role in affecting the overall remineralization process of the dentition. The use of supplements help to keep the levels at optimum and thus reduce the chances of treating very early lesion of caries. Hence the aim was to investigate the indirect effects of oral vitamin D3 on microhardness and elemental weight percentage of Calcium (Ca) and Phosphorous (P) in enamel surface with an artificially initiated carious lesion.

Methods

The 120 extracted premolars were randomly divided into five groups according to salivary immersion. Each group had a total of twenty-four participants, with the following characteristics: control +ve: sound enamel; control -ve: only subjected to pH cycle; A: pH cycle and immersion in control saliva; B: pH cycle and saliva collected after three weeks; and C: pH cycle and saliva collected after six weeks. The unstimulated saliva was collected from (40) adult volunteers receiving vitamin D3 1000IU gel capsules daily for six weeks. Before each vitamin D3 intake, 10 mL of unstimulated control saliva was collected from each participant. Then other 10 ml. were collected after three and six weeks of vitamin D receiving periods. Saliva immersion time (12 hours). Enamel surface was assessed by Vicker’s Microhardness machine and (X-ray fluorescence – XRF) spectrometer.

Results

For all specimens, there was a significant decrease in both (Ca and P weight %) after demineralization and then they significantly increased after receiving vitamin D3. The microhardness and elemental analysis provide confirmed results that were represented as a statistically significant difference at (P≤ 0.05) between groups that received vitamin D3 and those without vitamin D3 dosage.

Conclusions

Oral vitamin D3 has a significant potential in motivating remineralization of early lesions on the enamel surfaces representing improved surface microhardness and minerals content (Ca and P weight %) of demineralized tooth surfaces.

By |2022-06-15T00:01:33+00:00January 1st, 2022|Other|

Biological dentistry-whole body health shifting the paradigm in the 21st century.

Titanium is not only used in dental implants, but also in many dental materials and has shown to be toxic. Nickel braces, are often called “stainless steel”, as are nickel crowns. Nickel has been deemed to be carcinogenic, according to the National Toxicology Program, Department of Health and Human Services. When oral galvanism occurs, particles are released from the oral cavity and can translocate to other areas in the body, causing
potential toxicity and biological hazards

By |2022-11-12T23:57:23+00:00January 1st, 2022|Other|

Vitamin D and its role in oral diseases development. Scoping review.

Vitamin D is a fat-soluble secosteroid that plays a significant role in the whole body, including the maxillofacial region. The discovery of its receptors in many cells and organs made it possible to reveal the participation of vitamin D not only in the regulation of calcium phosphate metabolism, but also in immune processes, in providing anti-inflammatory and antimicrobial effects, slowing down cell proliferation and stimulating differentiation. In this literature review, we demonstrate the association between low vitamin D levels and the development of recurrent aphthous stomatitis, the course and response to treatment of squamous cell carcinoma of the oral cavity, the severity of periodontal diseases, and the processes of osseointegration and bone remodeling during dental implantation and guided tissue regeneration. The aim of our article was to demonstate a possible connection between vitamin D level and the oral diseases that can be presented at an oral surgery appointment, which will help clinicians to reduce the risk of early dental implant failure, ensure favorable outcomes of augmentative operations, as well as decrease the destructive effects of severe periodontitis and other conditions throug knowledge and timely lab tests and endocrinologist prescriptions.

Root Canal Disinfection Articles with the Highest Relative Citation Ratios. A Bibliometric Analysis from 1990 to 2019.

The relative citation rate (RCR) is a normalized article-level metric useful to assess the impact of research articles. The objective of this bibliometric study is to identify and analyze, in root canal disinfection, the 100 articles having the highest RCRs in the period 1990-2019, then compare them with the top 100 articles most cited. A cross-sectional study was performed, and the search strategy ((Disinfection AND root canal) AND ((“1990/01/01″[Date-Publication]: “2019/12/31″[Date-Publication]))) relied on PubMed (n = 4294 documents), and article data were downloaded from the iCite database. The 100 articles with the highest RCRs and the top 100 cited were selected and evaluated in bibliometric terms. Among the 100 articles with the highest RCRs, there were no differences in the three decades for RCRs values, but there were in citations, being 2000-2009 the most cited. The USA was the predominant country (n = 30), followed by Brazil (n = 14). The most frequent study designs were reviews (n = 27) and in vitro (n = 25) and ex vivo (n = 24) studies. All subfields were well represented, although they varied over time. In 2010-2019, regenerative procedures and irrigation/disinfection techniques were predominant. Considering the RCR’s top 100 articles, 76 were common with the 100 most cited articles. Using the RCR metric allowed us to identify influential articles in root canal disinfection, a research field with topics of significance that fluctuate over time. Compared to citations, RCR reduces the time from publication to detection of its importance for the readership and could be a valid alternative to citation counts.

By |2022-08-29T22:55:06+00:00January 1st, 2022|Other|

Influence of Commonly Used Endodontic Irrigants on the Setting Time and Metal Composition of Various Base Endodontic Sealers.

The present study aimed to evaluate if commonly used endodontic irrigants such as 3% sodium hypochlorite (NaOCl, Prime Dental, Thane, India), 2% chlorhexidine (CHX, Sigma-Aldrich Co., St. Louis, MO, USA), and 17% ethylenediaminetetraacetic acid (EDTA, Meta-Biomed Co. Ltd., Cheongju-si, South Korea) influenced the setting time and metal composition of different base endodontic sealers on exposure. AH Plus (Dentsply De Trey GmbH, Konstanz, Germany), Sealapex (SybronEndo, Orange, CA, USA), mineral trioxide aggregate (MTA) Fillapex (Angelus Soluções Odontológicas, Londrina, Brazil), and Tubli-Seal (Kerr Dental, Orange, CA, USA) were selected as the different base representatives of endodontic sealers. These sealers were exposed to 3% NaOCl, 2% CHX, and 17% EDTA, and the individual setting time of the sealers was analyzed. The samples were analyzed for heavy metal elements such as chromium (Cr), nickel (Ni), cobalt (Co), cadmium (Cd), arsenic (As), mercury (Hg), lead (Pb), and beryllium (Be) by using inductively coupled plasma mass spectrometry (ICP-MS) analysis. For statistical analysis, one-way ANOVA and post hoc Tukey’s tests were used. All selected sealers showed variation in setting time post-exposure to different irrigants. MTA Fillapex had the shortest mean setting time (215.7 min, post-exposure at 187.3 min) (p < 0.05). Mean setting time was also affected for AH Plus (479.6 min, post-exposure at 423.9 min) (p < 0.05) and Tubli-Seal (514.7 min, post-exposure at 465.2 min) (p < 0.05). Sealapex showed the maximum reduction of setting time (864.8 min, post-exposure at 673.4 min) (p < 0.05). All tested sealers showed heavy metals (Cr, Ni, Co, Cd, As, Hg, and Pb) in their composition, and the quantities were influenced by interaction with different irrigants. The heavy metal Be was not seen in any of the samples. Sealapex showed the longest setting time in comparison to other test sealers. Heavy metals were most present in Sealapex, followed by AH Plus, Tubli-Seal, and MTA Fillapex. MTA Fillapex was seen to have the shortest setting time, and heavy metal composition was least affected on interaction with different commonly used endodontic irrigants. Further, this study provides significant insight into the influence of different endodontic irrigants on interaction with different base endodontic sealers, which has not been reported previously, and future studies should emphasize endodontic irrigant-sealer interactions and their possible effects in the long run.

Diagnostic tests for titanium hypersensitivity in implant dentistry: a systematic review of the literature.

Purpose: There are rising concerns about titanium hypersensitivity reaction regarding dental endosseous implants. This review aims to summarize and compare the validity and reliability of the available dermatological and laboratory diagnostic tests regarding titanium hypersensitivity. The following PICO design was used: In Patients with titanium dental implants (P) does epicutaneous testing (ECT) (I), compared to lymphocyte transformation test (LTT) or Memory Lymphocyte Immunostimulation Assay (MELISA) (C) detect hypersensitivity reactions (O)? A literature search was performed including all studies dealing with this topic. Studies regarding orthopedic implants were excluded.

Methods: Three databases (MEDLINE PubMed, Cochrane Library, SciELO) were screened for suitable studies and an additional manual search was also performed. Literature regarding hypersensitivity reactions in orthopedic implants, hypersensitivity reactions regarding implants not related to dental or maxillofacial surgery, animal studies and in vitro studies were excluded. A quality assessment of all selected full-text articles was performed. Randomized, controlled trials were evaluated with the Cochrane Risk of Bias Tool I. Cohort studies were assessed according to the New Castle-Ottawa Scale and case series according to Moga et al. (Development of a quality appraisal tool for case series studies using a modified Delphi technique. 2012).

Results: 10 studies were included in the quantitative synthesis and available for the endpoint diagnostics of intolerance reactions to titanium dental implants: 2 clinical studies, 7 cohort studies and 1 case series. The potential for bias (internal validity) for these studies was overall rated as high.

Conclusions: The study of the available literature regarding ECT and MELISA or LTT in patients with suspected titanium hypersensitivity showed inconsistent results in terms of reliability and validity and thus, those tests should be regarded cautiously. There is strong evidence that titanium hypersensitivity in dental implants is associated with innate immunity: unspecific pro-inflammatory responses due to particle induced hyperreactivity of macrophages or toxicological responses especially towards nanoparticles rather than activation of the adaptive immune system. Therefore, tests detecting allergies do not seem expedient and inflammatory clinical signs should be regarded as leading parameters.

Color change after tooth bleaching with ozone and 10% ozonized carbamide peroxide for in-office use.

There is a constant search for bleaching treatments that can offer greater safety with fewer adverse effects, especially in the techniques performed in the office, which usually employ hydrogen peroxide in high concentrations (35% to 40%) that are not recommended by some international control agencies. This in vitro study evaluated the color change after tooth bleaching with the use of ozone and a 10% ozonized carbamide peroxide bleaching treatment for in-office use. Thirty molars were allocated (n = 10): three applications of ozone (1 hour every 3 days); three applications of 10% ozonized carbamide peroxide (1 hour every 3 days); 10% carbamide peroxide agent (8 hours a day for 7 days). The teeth were mounted on a plaster model to simulate the dental arch, and trays made of silicone were used for the application of the bleaching agents and to allow ozone to enter through. The ozone concentration used was 60 μg/mL, with an oxygen flow of 0.25 L/min. The values of color change showed no significant differences among treatments. The variations in the parameters over time, as well as the values of ΔEab, ΔE00, and WID, showed that there was no significant difference among the three treatments. The use of ozone and 10% ozonized carbamide peroxide for in-office use was effective for tooth bleaching with clinically perceptible and acceptable color alterations. The study was approved on September 10, 2019 by the São Leopoldo Mandic Ethics Research Committee (CAAE No. 17711719.4.0000.5374).

Childhood malnutrition and hypo mineralized molar defects; a cross sectional study, Egypt

Background: Malnutrition is well-known to yield high morbidities and it has pre-eruptive and post-eruptive consequences. The objective of the study was to evaluate the prevalence of Hypomineralized Second Primary Molars (HSPM), Molar Incisor Hypomineralization (MIH) and dental caries in malnourished children, as well as addressing the relation between types of malnutrition and the dental morbidities. Methods: This is a cross sectional analytical study. A consecutive sample of 54 malnourished cases aged 5-10 years and presented to the Outpatient Clinic of Pediatric Dentistry Department, Faculty of Dentistry, Cairo University across 6 months period were examined for HSPM, MIH – using the European Academy of Pediatric Dentistry criteria – and dental Caries using def/ DMF indices. Outcomes were the presence or absence of MIH and HSPM and their levels measured as percentage as well as Caries Indices. Exposures were types of malnutrition and the socioeconomic status. Results : The mean age of study participants was 7.10 ± 1.34 years. HSPM and MIH were found in 47.2% and 45.2% of the study participants respectively, while dental caries was observed in 83% and 64.3% for primary and permanent teeth respectively. There was co-occurrence between HSPM and MIH in 39% of the cases. HSPM level was significantly different in various types of malnutrition. It showed significant difference between the stunted group (median HSPM of 14.2%) and the overweight or obese group (median HSPM of 0.0%) (P value 0.01). MIH level showed significant differences between the stunted group (median MIH of 19.4%) and overweight or obese group (median MIH of 0.0%) (p value 0.001), as well as between the stunted group (median MIH of 19.4%) and wasted group (median MIH of 0.0%) (p value 0.025). Conclusions : Malnourished children have high prevalence of dental abnormalities. HSPM could expect the presence of MIH.

By |2022-09-19T21:16:39+00:00January 1st, 2022|Other|

Prevalence of vitamin D inadequacy and bone turnover markers concerning bone mineral density in older persons.

Owing to the early tooth loss in a large population, the need for removable prosthodontic therapy has widely increased. Loss of teeth can occur due to trauma, periodontal disease, dental caries, and/or oral health negligence. The removable prosthesis is preferred over other teeth replacement methods owing to its cost-effectiveness. However, due to continuous alveolar bone resorption, relining of the removable prosthesis is needed regularly. We aimed to assess the prevalence of vitamin D deficiency and bone turnover marker concerning bone mineral density. Eighty complete denture wearers either in the maxilla or in the mandible or both constituted the study sample. Before the study, all subjects were explained the procedures of the study, and informed consent was obtained before proceeding with the study. Subjects were instructed to provide an early morning sample in a fasting state as serum osteocalcin (OCN) and C-terminal telopeptide (C-Tx) have diurnal variations. Blood samples were collected, and samples were ruled out for 25-OH vitamin D, serum OCN, and C-TX. To determine the association between frequency of relining and bone turnover marker, the collected data were subjected to statistical evaluation. Significant correlations were seen between bone C-Tx, turnover markers (p<0.001), and frequency of denture relining and osteocalcin (p<0.001). No statistically significant effect of gender, vitamin D levels, age, calcium levels, vitamin D supplements, and diabetes was seen on denture relining frequency. The present study concludes that an elevated level of the bone turnover markers such as OCN and C-Tx increases the frequency of relining.

By |2022-08-23T22:24:52+00:00January 1st, 2022|Other|
Go to Top